a10 Sensor EXamples for Structural Dynamics Example: fixed-fixed Goal: Explain what they measure and how they work beam with center load laser sensors excitation accelerometers gyroscopes strain gages m load cells inductive sensors shaker EI ground First flexible mode frequency: 0=14 F(m+0.375m) 16.810(16682) assachusetts Institute of Technology
6HQVRU([DPSOHVIRU6WUXFWXUDO'\QDPLFV ([DPSOHIL[HGIL[HG *RDO([SODLQZKDWWKH\PHDVXUHDQGKRZWKH\ZRUN EHDPZLWKFHQWHUORDG VKDNHU ODVHUVHQVRUV DFFHOHURPHWHUV OV LYH VHQVRUV )L O ( ) Q E (, OP P ω = + PE P O VWUDLQJDJHV J\URVFRSHV ORDGFHO JURXQG LQGXFW H[FLWDWLRQ UVWI H[LEOHPRGHIUHTXHQF\
GG.aln Strain Gages Strain △ Strain gages measure strain differential displacement over a finite area via a change in electrical resistance R=lp[Q2 Current Nominal length io: I( With applied strain: I (+△)p implementation Wheatstone bridge iaY ni balance circuit bond to test article strain gages feature polyimide-encapsulated GND constantan grids with V+ copper-coated solder tabs Mfg Ref:http://www.measurementsgroup.com 16.810(16682) assachusetts Institute of Technology Ui
6WUDLQ*DJHV 6WUDLQ ∆O 6WUDLQJDJHVPHDVXUHVWUDLQGLIIHUHQWLDO GLVSODFHPHQWRYHUDILQLWHDUHDYLDD ε = FKDQJHLQHOHFWULFDOUHVLVWDQFH5 Oρ >Ω@ OR &XUUHQW1RPLQDOOHQJWKO , = 9LQ R R ORρ OR :LWKDSSOLHGVWUDLQ ,ε = 9LQ OR + ∆Oρ ,PSOHPHQWDWLRQ :KHDWVWRQHEULGJH FLUFXLW ERQGWRWHVW VWUDLQJDJHVIHDWXUH DUWLFOH SRO\LPLGHHQFDSVXODWHG *1' FRQVWDQWDQJULGVZLWK FRSSHUFRDWHGVROGHUWDEV 9 0IJ 5HIKWWSZZZPHDVXUHPHQWVJURXSFRP
IG aln Accelerometers Accelerometers measure linear acceleration in one, two or three ¥()→s2X(s-3 axes. We distinguish (generally neglect initial conditions) single Vs. multi axis accelerometers mag +40db/dec DC versus non-DC accelerometers rolloff Recorded voltage response to base motion 1(t)=K(t)+V out Can measure: linear, centrifugal and gravitational acceleration Use caution when double-integrating acceleration to get position(drift) Single-Axis C1 Accelerometer must be aligned with sensing axis C2 Example: Kistler Piezobeam (not responsive at Dc Example: Summit capacitive Manufacturers: Kistler. Vibrometer Summit accelerometer Dc capable) 16.810(16682) Massachusetts Institute of Technology
$FFHOHURPHWHUV $FFHOHURPHWHUVPHDVXUHOLQHDU DFFHOHUDWLRQLQRQHWZRRUWKUHH D[HV:HGLVWLQJXLVK VLQJOHYVPXOWLD[LVDFFHOHURPHWHUV '&YHUVXVQRQ'&DFFHOHURPHWHUV → V ; V − V[ − G[ [ W GW JHQHUDOO\QHJOHFWLQLWLDOFRQGLWLRQV PDJ $FFHOHURPHWHU UHVSRQVHWR EDVHPRWLRQ G%GHF UROORII 5HFRUGHGYROWDJH 9 W = .[W +9 ω RXW D &DQPHDVXUHOLQHDUFHQWULIXJDODQGJUDYLWDWLRQDODFFHOHUDWLRQ 8VHFDXWLRQZKHQGRXEOHLQWHJUDWLQJDFFHOHUDWLRQWRJHWSRVLWLRQGULIW 6LQJOH$[LV & $FFHOHURPHWHUPXVWEH DOLJQHGZLWKVHQVLQJD[LV & ([DPSOH.LVWOHU3LH]REHDP QRWUHVSRQVLYHDW'& ([DPSOH6XPPLWFDSDFLWLYH 0DQXIDFWXUHUV.LVWOHU9LEURPHWHU6XPPLW DFFHOHURPHWHU'&FDSDEOH D
in Laser Displacement sensors sensor Records displacement directly x()→>X(s) via slant range measurement TVDC cal Settings 1: 2um-60 ms II: 15um-2ms target l:50m0.15ms0 Resolution tradeoff patlal vs temporal Distance x is recorded via triangulation . 7 between the laser diode(emitter), the target and the receiver range. (position sensitive device -PSD) Advantages Vibrometers include advanced processing contact-free measurement and scanning capabilities Disadvantages Manufacturers: Keyence, MTI Instruments need reflective, flat target limited resolution 1 g 16.810(16682) Massachusetts Institute of Technology Ui
/DVHU'LVSODFHPHQW6HQVRUV 5HFRUGVGLVSODFHPHQWGLUHFWO\ GLVSODFHPHQWGLUHFWO\ YLDVODQW UDQJH YLDVODQWUDQJHPHDVXUHPHQW WDUJHW [W ; V → 9RXW [>P@ >9'&@ 'LVWDQFH[LVUHFRUGHGYLDWULDQJXODWLRQ EHWZHHQWKHODVHUGLRGHHPLWWHUWKH WDUJHWDQGWKHUHFHLYHU [ VHQVRU &/ UDQJH 7\SLFDO6HWWLQJV , µPPV ,, µPPV ,,, µPPV 5HVROXWLRQWUDGHRII VSDWLDOYVWHPSRUDO SRVLWLRQVHQVLWLYHGHYLFH 36' $GYDQWDJHV 9LEURPHWHUVLQFOXGHDGYDQFHGSURFHVVLQJ FRQWDFWIUHHPHDVXUHPHQW DQGVFDQQLQJFDSDELOLWLHV 'LVDGYDQWDJHV 0DQXIDFWXUHUV.H\HQFH07,,QVWUXPHQWV QHHGUHIOHFWLYHIODWWDUJHW OLPLWHGUHVROXWLRQa µP
IGA10 Force Transducers/ Load cells Force Transducers/Load Cells are capable of measuring Up to 6 dOF of force on three orthogonal axes, and the moment (torque)about each axis, to completely define the loading at the sensor's location The high stiffness also results in a high resonant frequency allowing accurate sensor response to rapid force changes Load cells are electro-mechanical transducers that translate force or weight into voltage Mz My They usually contain strain gages internally F Manufacturers: JR3, Transducer techniques Inc 16.810(16682) Massachusetts Institute of Technology 10
)RUFH7UDQVGXFHUV/RDG&HOOV )RUFH7UDQVGXFHUV/RDG&HOOVDUHFDSDEOHRIPHDVXULQJ 8SWR'2)RIIRUFHRQWKUHHRUWKRJRQDOD[HV DQGWKHPRPHQWWRUTXHDERXWHDFKD[LVWR FRPSOHWHO\GHILQHWKHORDGLQJDWWKHVHQVRU VORFDWLRQ 7KHKLJKVWLIIQHVVDOVRUHVXOWVLQDKLJKUHVRQDQWIUHTXHQF\ DOORZLQJDFFXUDWHVHQVRUUHVSRQVHWRUDSLGIRUFHFKDQJHV /RDGFHOOVDUHHOHFWURPHFKDQLFDOWUDQVGXFHUV WKDWWUDQVODWHIRUFHRUZHLJKWLQWRYROWDJH 7KH\XVXDOO\FRQWDLQVWUDLQJDJHVLQWHUQDOO\ 0DQXIDFWXUHUV-57UDQVGXFHU7HFKQLTXHV,QF )[ )] )\ 0[ 0] 0\