H APPARATUS &AGENTSAPPARATUSa.Mammal animal operating apparatusb.Tracheal cannulac.Syringe(30ml and 50ml respective)d. A rubble tube 50cm in lengthe. A bladder of ball filled with CO2f.Protectiveelectrodeg. Power Lab SystemAGENTS:a.20%urethaneb.0.9% saline solutionc. 3% lactic acid
Ⅱ APPARATUS & AGENTS APPARATUS a. Mammal animal operating apparatus b. Tracheal cannula c. Syringe(30ml and 50ml respective) d. A rubble tube 50cm in length e. A bladder of ball filled with CO2 f. Protective electrode g. Power Lab System AGENTS: a. 20% urethane b. 0.9% saline solution c. 3% lactic acid
III Preparations before operation 1 Anesthesia: 20% urethane (5mg/kg) isadministered through the marginal vein' in theear.The position where we begin to inject anestheticshould be near to distal of marginal ear as possibleas we can.The velocity of injection should be slow and weshould monitor the respiration of the animal
◼ 1 Anesthesia: 20% urethane (5mg/kg) is administered through the marginal vein in the ear. The position where we begin to inject anesthetic should be near to distal of marginal ear as possible as we can. The velocity of injection should be slow and we should monitor the respiration of the animal. Ⅲ Preparations before operation
III Preparations before operation 2 Fixing: After anesthesia, therabbit is fixed.We should lay the rabbit on its back onthe operation table, then fix the limbswith the help of the ropes
Ⅲ Preparations before operation ◼ 2 Fixing: After anesthesia, the rabbit is fixed. We should lay the rabbit on its back on the operation table, then fix the limbs with the help of the ropes