Series 90-30 PLC Memory Three Types of On-Board Memory Battery Backed RAM EPROM EEPRoM or FLAsH Memory Card for Program Transportability Not Models 350 or highter Series90-30-02/28/94
Series 90-30 - 02/28/94 p11 Series 90TM -30 PLC • Three Types of On-Board Memory - Battery Backed RAM - EPROM - EEPROM or FLASH • Memory Card for Program Transportability – Not Models 350 or highter Memory
Series 90-30 PLC Topics 90-30 Power Supply yO Module characteristics Module selection Analog lo characteristics Series9030-022894
Series 90-30 - 02/28/94 p12 Series 90TM -30 PLC Topics • 90-30 Power Supply • I/O Module Characteristics • Module Selection • Analog I/O characteristics
Series 90-30 PLC 90-30 Power Supply 100-240 VAC Auto Ranging 48-65 Hz Auto Ranging 125 VDC 24-48 VDC Auto Ranging Modular Power Supply Common Across 90-30 Family 24Vdc Available to User Up to 250 mA 24 VDC Available Series9030-022894
Series 90-30 - 02/28/94 p13 Series 90TM -30 PLC 90-30 Power Supply • 100-240 VAC Auto Ranging • 48-65 Hz Auto Ranging • 125 VDC • 24-48 VDC Auto Ranging • Modular Power Supply • Common Across 90-30 Family • 24Vdc Available to User • Up to 250 mA @ 24 VDC Available SERIES90-30 BASE5-SLOTzz WITH CPU CAUTION USER PROGRAM AND REGISTER VALUESMAYBE LOST IF POWER SUPPLY IS REMOVEDFOR LONGERTHAN 1 HOUR 1 POWER SUPPLY 1 2 3 4 5 System PROM Program PROM POWER SUPPLY GE Fanuc SERIES 90-30 PROGRAMMABLE CONTROLLER + 24VDC OUTPUT - 100-240 VAC 40A 50/60HZ B A T T E R Y PWR OK RUN BATT Socket Release Open Close
Series 90-30 PLC yo Module characteristics Common l/O for 30 Family Enclosed modules B12345678 B12345678 Removable Terminal block RELAY N OZ AMP OUTPUT No Tools Required for Insertion or Extraction Common to all discrete and Analog l/O LED Matrix- per Point ◎ Indication ◎ Blown Fuse Indicator 44A726782-015 Fused Outputs > 5 Amps e6C94 Wiring Diagram Series9030-022894
Series 90-30 - 02/28/94 p14 Series 90TM -30 PLC I/O Module Characteristics • Common I/O for 30 Family • Enclosed Modules • Removable Terminal Block • No Tools Required for Insertion or Extraction • Common to all Discrete and Analog I/O • LED Matrix - per Point Indication • Blown Fuse Indicator • Fused Outputs > .5 Amps • Wiring Diagram A1 2 3 4 5 6 7 8 B1 2 3 4 5 6 7 8 F RELAY N.O. OUTPUT 1 3 2 A1 A2 A3 5 A4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 4 A5 A6 A7 A8 B1 B2 B3 B4 B5 B6 B7 B8 V V V V 2 AMP 44A726782-015 FOR USE WITH IC693MDL940 12/24 VDC 0.5A. B1 OUTPUT A1 A2 A3 A3 A4 A5 A6 A7 A8 B2 B3 B4 B5 B6 B7 B8 SLOT A 1 2 3 4 5 6 7 8 B 1 2 3 4 5 6 7 8 F
Series 90-30 PLC Module selection INPUT OUTPUT MIXED 32 Point 32 Point 24 Vdc 8.16.32 Point 8.16,32 Point 8 In, Relay out 24 Vac 16 Point (Use Relay Output) 125 Vdc 8 Point 6 Point isolated 120 Vac 16 Point 12.16 Point 8 In, 8 Relay out 8 Point isolated 5. 8 Point Isolated 240 Vac 8 Point Isolated 5. 8 Point Isolated Relay NA 16 Point 8 Point isolated Analog 4 Channel 2 Channel 4 In. 4 Out 16 Channel 8 Channel Future Series9030-022894
Series 90-30 - 02/28/94 p15 Series 90TM -30 PLC Module Selection INPUT OUTPUT MIXED TTL 32 Point 32 Point 24 Vdc 8, 16, 32 Point 8,16,32 Point 8 In, Relay Out 24 Vac 16 Point (Use Relay Output) 125 Vdc 8 Point 6 Point Isolated 120 Vac 16 Point 12,16 Point 8 In, 8 Relay Out 8 Point Isolated 5, 8 Point Isolated 240 Vac 8 Point Isolated 5, 8 Point Isolated Relay N/A 16 Point 8 Point Isolated Analog 4 Channel 2 Channel 4 In, 4 Out * 16 Channel 8 Channel * * Future